   ID   Product   Manufacturer   Model #   Model 2   Status 
 2551 Microscope:Camera  Hamamatsu  C4742-95-12NR    Available 
Description/Details:
The ORCA-HR is a high resolution digital camera using a large format interline CCD chip with no mechanical shutter. In addition to a high resolution of 10 million pixels. a wide dynamic range of 12 bit digital output and high sensitivity offers a wide application range down to low light level imaging. Peltier cooling drastically reduces dark noise and minimizes thermal drift. which makes the camera an ideal choice for demanding scientific and industrial applications. Features High resolution of 10 million pixels Lens coupling : F-mount. ENG (optional) Low dark noise with peltier cooling Full remote control from PC via RS-232C Vertical overflow drain structure Anti-blooming function Large format interline CCD chip with no mechanical shutter Shortest exposure time : 330 µs capture fast events Binning (2 ×2. 4 ×4) function to improve sensitivity Imaging device Large format interline CCD (HR-1000) Wavelength (min.) 320 nm Wavelength (max.) 980 nm QE (max.) 50% ... 

 5325 Microscope:Camera  Nikon  UFX-II    Available 
Description/Details:
Polaroid film camera 

 5324 Microscope:Camera  Nikon  U-III    Available 
Description/Details:
Multi-Point Sensor System w/ remote NIKON - U-III Advanced Auto-Photomicrographic Film Camera The U-III's compact, sleek design and advanced exposure system with Multi-point sensor, make it the system of choice for serious fluorescence applications including FISH. It is ideal for use at research institutes and universities and wherever quick, precise exposure settings are essential. Details • Fluorescent Control Panel LCD display with backlight illumination for easy key entry, even in the dark • Highly-sensitive multipoint sensor to ensure accurate exposure from average light measurement of 35% down to spot measurement. This is essential for determining exposures for microscopic specimens • Multipoint sensor automatically determines optimum exposure by rapidly scanning the target area • Features same swing-out beamsplitter system and direct projection lens system as the H-III and P-III, which delivers 100% of the light to the film for the fastest exposure... 

 6160 Microscope:Camera  Roper Scientific  Quantix    Available 
Description/Details:
Quantix® is an F-mount or C-mount, air-cooled imaging system for acquiring digital scientific data. The system provides a fast focus, fast frame rate, and fast readout rate, while still providing the ability to acquire low-light images by integrating over long periods of time Details: Roper Scientific Quantix (KAF1401E) 1.4 MegaPixel Air Cooled Includes PCI Interface card, cable and Power supply Features: Scientific-Grade CCD Single-window Imaging Path ITO Transparent Gates Three Detection Modes Flexible Binning and Readout 12-Bit Digitization Thermoelectric Cooling Compact Camera Head ... 

 2593 Microscope:Camera & Controller  Carl Zeiss  MC 80 DX    Available 
Description/Details:
Camera and controller sold together. The MC 80 DX Microscope Camera is a photomicrographic camera, which fits all Zeiss microscopes having a standard camera port. The MC 80 DX Microscope Camera fits to the standard camera port of Zeiss microscopes via a camera adapter sleeve. There are different adapters, to be used depending on whether the microscope has a camera port for 60 mm or 44 mm image distance. All camera functions of the MC 80 DX are controlled through a control Console with a clearly arranged operating panel providing operator guidance. Its automatic exposure function and easy operation makes the MC 80 DX ideal for photomicrographic routine. The MC 80 DX provides the following functions: Automatic exposure, with exposure metering averaged over the central 30% of the frame. Automatic reading of the ISO film speed rating from DX-coded 35 mm film cartridges. Automatic film leader winding and film advance; power rewinding. Method-specific exposure corrections (+2 ... -3 exp... 

 4597 Microscope:Camera Controller  Optronics Engineering  DEI-470    Available 
Description/Details:
Microsope Video Cameras with Built-in Digital Imaging. Digital Edge Sharpening convolution filter operates in real-time to expand the finedetails of soft-focus or low contrast images. The unique filter enhances video prints andcomputer images to more closely resemble the subjects as viewed in the microscope oculars. Digital Contrast & Brightness Enhancement enable control of video gain and offset to improve dim, low contrast images due to fading and weak fluorochrome emissions. The Video System Controller contains a built-in 1.5 megabyte 24 bit frame grabber to allow freeze frame imaging. No external microprocessor is required. The controller is preprogrammed to withstand the rigors of a multi-user environment. ... 

 3558 Microscope:Controller  Olympus Co  PM-CB20  Exposure Control Unit  Available 
Description/Details:
The control box for the Olympus PM-20 camera has a liquid crystal display that permits user-controlled entry for such items as film size, ISO rating of film, exposure adjust for unusual lighting conditions, reciprocity setting, automatic ISO setting for DX coded film, double exposure capability, exposure lock, bracketing exposure settings, color temperature accessory, lighted frame for fluorescence, and several other variables. The PM-20 has a built-in silicon photodiode system whose meter reads the central 30 percent of the field of view or, using the spot meter lever, the central 1 percent of the field of view. The automatic exposure meter reads the "live" image continuously until the shutter closes. The PM-20 has a setting for fluorescence microscopy whose algorithm automatically reduces the exposure time by 80 percent to prevent overexposure.... 

 2555 Microscope:Controller  LEJ  FluoArc BP    Available 
Description/Details:
Automatic signal balance for image recording: FluoArc permits you to control the intensity of the excitation light via the brightness of the light source and therefore to receive signals of the required intensity. In computer-controlled multichannel fluorescence, the light intensity changes automatically. Manually or digitally controlled: FluoArc always provides optimum signals for perfect results.... 

 4653 Microscope:Light Source  Schott Fostec LLC  DCR II    Available 
Description/Details:
DCR II is a 150-watt regulated light source. Low voltage ripple is rated at only 1 percent peak to peak. The regulated power supply eliminates flicker dips and surges, providing a stable light output. The power supply regulates line voltage fluctuations of up to ± 15 percent and the light generated will not vary more than ± .5 percent. A built-in 9-pin connector can be accessed with an analog input (0 to 5 VDC) to control light intensity. Rated Power Output 200 Watts Output Voltage 0.0, 0.5 to 20.5 VDC Input Voltage Rating, 50/60 Hz. 90 to 265 VAC Power Factor Correction @ 230 VAC, 50 Hz. > 0.99, < 4° Hold-up Time, Nominal AC Input, Full Load 8.3 milliseconds Line Regulation, Over Entire Input Range ±0.05% Current Limit Set Point 8.5 Amps Temperature Range: Operating 0° to 45°C Storage -25° to 85°C Relative Humidity, Non-condensing 5% to 95% Vibration Tests: 3 Orthagonal Axes, 0.75g peak, 5 to 500Hz at 1 oct/min. 2 hrs. each axis, 1.5g for 5 m... 

 6079 Microscope:Light Source  Cole Parmer  41720-20  PL8011BN1CP2  Available 
Description/Details:
Illuminators These fiber optic illuminators use 60% intensity for maximum bulb life. Separate switches (on/off and intensity control) enable you to maintain the desired light intensity setting when the unit is on or off. standard bulb 09741-02. Standard and deluxe 115 VAC models also include a 7 1/2-ft cord with US standard plug and are UL-listed and CSA-certified and TUV approved for laboratory use, and have the CE mark. Standard Illuminator is equipped with an infrared filter that reduces the transmittance of heat to your sample to virtually zero. Perfect when working with temperature sensitive-samples and biologicals. Specifications Lamp intensity 40,000 footcandles at 3" Lamp color temp 3250 K with standard bulb 09741-02 Bulb life 200 hours at high setting Watts 150 watts Power 115 VAC, 50/60 Hz Illuminator dimensions 9"L x 7 1/4"W x 4 5/8"D ... 

 4815 Microscope:Light Source Housing  Opti Quip  770  Lamphouse  Available 
Description/Details:
 

 2561 Microscope:Light Source Power Supply  LEJ  FluoArc001.26A    Available 
Description/Details:
Usable with HBO 100 and HBO 100 self-adjusting. Intensity regulation: 20% to 100%. Wide-range power unit 100V...240V, 50/60Hz. Incl. country-specific line cable. ... 

 3142 Microscope:Light Source Power Supply  LEP  HBO100  990014  Available 
Description/Details:
Power supply for HBO100 mercury arc lamp. 

 4594 Microscope:Power Supply  Carl Zeiss  1100    Available 
Description/Details:
Power supply for microscope lamp.