ID |
Product |
Manufacturer |
Model # |
Model 2 |
Status |
|
 | ALS1260 | Alpha Block | MJ Research | ALS-1260 | 60 Well | Available |
Description/Details: The “60” for 0.5ml Tubes
For years the block that holds sixty 0.5ml microfuge tubes has been popular with researchers. Many prefer this format because the tubes are easy to use, economical, and each is large enough to write on. ... |
|
|
 | ALS1200 | Alpha Block | MJ Research | ALS-1200 | Flat | Available |
Description/Details: The Flat Block for Microarrays and Customized Attachments
The Flat Block surface is ideal for arrays and chips. It also has 4 small screw-down points so that a custom-machined sample block may be easily attached. This provides the flexibility to customize our thermal cyclers for specific needs. ... |
|
|
 | ALS1296 | Alpha Block | MJ Research | ALS-1296 | 96 Well | Sold |
Description/Details: The “96V” for 0.2ml Tubes or V-well Plates
This sample format can hold one V-bottom microplate, or 96 x 0.2ml tubes, or strips of 0.2ml tubes. These V-well vessels are specifically designed for thermal cycling, and have become the industry standard. The 96-well format blocks feature gradient capability and are used in Opticon™ real-time systems. ... |
|
|
 | ALS1238 | Alpha Block | MJ Research | ALS-1238 | 384 Well | Available |
Description/Details: The “384” for 384-well Plates
MJ Research has worked with several genome centers to develop a high density format for automated operation. The result is the 384-well Alpha unit, a true 4X version of the 96-well format. The wells have the same V-profile as the 96V, and are spaced on 4.5mm centers. ... |
|
|
 | ALD1233 | Alpha Block | MJ Research | ALD-1233 | Dual 30/30 Well | Available |
Description/Details: Description - Hot Swappable Dual Alpha Block for MJ Research DNA Engine (PTC-200, PTC-225, Tetrad II PTC-240 and MJ Research Dyad) Allow two independent protocols to run simultaneously on the same base. Each side of the 30x30 block holds 30 x 0.5ml tubes and has its own heated lid with thumbwheel adjustment.
... |
|
|
 | 4903 | Alpha Block | Applied Biosystems | GeneAmp 9700 | N384S9010409, Dual 384 Well | Available |
Description/Details: The module contains two aluminum sample blocks which operate in tandem. Each block, in turn, contains 384 sample wells and provides oil-free operation and a sample volume range of 5-20 micron-L(1). Specially designed MicroAmp(R) Reaction Plates are also available, as well as clear adhesive films for sample sealing.
Manufactured with the same user-friendly interface and intuitive application software that is standard with the GeneAmp(R) PCR System 9700, the dual 384-well module is easy to learn and simple to operate. ... |
|
|
 | 4902 | Alpha Block | Applied Biosystems | GeneAmp 9700 | 4314445R, 96 Well | Available |
Description/Details: Refurbished
Standard 0.2 mL aluminum, silver format
and sample block options
provide enhanced performance
and durability... |
|
|
 | 4901 | Alpha Block | Applied Biosystems | GeneAmp 9700 | 4314445, 96 Well | Available |
Description/Details: Aluminum 96-Well GeneAmp® PCR System 9700, Sample Block Module |
|
|
 | ALD1244 | Alpha Block | MJ Research | ALD-1244 | Dual 48/48 Well | Pending |
Description/Details: The “48/48” Dual Block for 0.2ml Tubes
Allows two independent protocols to be run simultaneously on the same cycler bay. Each side of the 48/48 holds 48 x 0.2ml tubes, and has its own heated lid with thumbwheel adjustment. The 0.2ml format works especially well in oil-free operation with small volumes (> 5µl).... |
|
|
 | ALD1234 | Alpha Block | MJ Research | ALD-1234 | Dual 30/48 Well | Available |
Description/Details: The “30/48” Dual Block for 0.5ml & 0.2ml Tubes
Allows two independent protocols to be run simultaneously on the same cycler bay. One side holds 30 x 0.5ml tubes; the other holds 48 x 0.2ml tubes or a 48-well plate. Each block has its own heated lid with thumbwheel adjustment. ... |
|
|
 | 5392 | Alpha Block | Applied Biosystems | 7900HT | 4316598, 384 Well | Available |
Description/Details: The Applied Biosystems 7900HT Fast Real-Time PCR System is a high-throughput real-time PCR system that detects and quantitates nucleic acid sequences. The interchangeable fast 384-well block capability combined with the optional Automation Accessory offers unmatched flexibility. Sample tracking is greatly simplified with the use of hand-held and integrated bar code readers. These features make the 7900HT system ideally suited to meet the high throughput requirements of today’s drug discovery process. Key applications include gene expression quantitation and the detection of single nucleotide polymorphisms (SNPs) using the fluorogenic 5’ nuclease assay. The 7900HT uses a Peltier-based thermal cycling system and an extended-life 488 nm argon-ion laser excitation source.
... |
|
|
 | 6461 | Alpha Block | Applied Biosystems | 7900HT | 4316592, 96 Well | Available |
Description/Details: The Applied Biosystems 7900HT Fast Real-Time PCR System is a high-throughput real-time PCR system that detects and quantitates nucleic acid sequences. The interchangeable fast 384-well block capability combined with the optional Automation Accessory offers unmatched flexibility. Sample tracking is greatly simplified with the use of hand-held and integrated bar code readers. These features make the 7900HT system ideally suited to meet the high throughput requirements of today’s drug discovery process. Key applications include gene expression quantitation and the detection of single nucleotide polymorphisms (SNPs) using the fluorogenic 5’ nuclease assay. The 7900HT uses a Peltier-based thermal cycling system and an extended-life 488 nm argon-ion laser excitation source.... |
|
|
 | 6465 | Alpha Block | Applied Biosystems | 7900HT | 4316592, 96 Well - Fast | Available |
Description/Details: The Applied Biosystems 7900HT Fast Real-Time PCR System is a high-throughput real-time PCR system that detects and quantitates nucleic acid sequences. The interchangeable fast 384-well block capability combined with the optional Automation Accessory offers unmatched flexibility. Sample tracking is greatly simplified with the use of hand-held and integrated bar code readers. These features make the 7900HT system ideally suited to meet the high throughput requirements of today’s drug discovery process. Key applications include gene expression quantitation and the detection of single nucleotide polymorphisms (SNPs) using the fluorogenic 5’ nuclease assay. The 7900HT uses a Peltier-based thermal cycling system and an extended-life 488 nm argon-ion laser excitation source.... |
|
|
 | 2865 | DNA:Sample Prep | Applied Biosystems | Prism | 6100 | Available |
Description/Details: The fast, versatile ABI PRISM™ 6100 Nucleic Acid PrepStation delivers superior throughput at a fraction of the cost of other systems.
Isolates highly pure nucleic acids free of cross-contamination, providing reliable results
Automates key processes, ensuring easy, high-throughput purification
Purifies up to 96 samples of total RNA or genomic DNA samples from a variety of biological sources, providing application flexibility
Fast, small, versatile, and affordable
The ABI PRISM™ 6100 Nucleic Acid PrepStation isolates and purifies nucleic acids, including total RNA and genomic DNA from a variety of biological samples. Just add the reagents, and the integrated vacuum system and embedded firmware will perform all other operations. In addition, a graphical user interface provides easy access to pre-programmed methods and lets you create, edit, and store custom purification routines.
... |
|
|
 | 4722 | DNA:Sample Prep | Qiagen | BioRobot EZ1 | | Available |
Description/Details: The BioRobot EZ1 workstation purifies high-quality nucleic acids from clinically relevant samples, such as whole blood. 1-6 samples are processed in 15-20 minutes. The rapid speed of nucleic acid purification is achieved through magnetic particle technology: nucleic acids in sample lysates are isolated in one step through their binding to the silica surface of magnetic particles.
... |
|
|
 | 4802 | DNA:Sample Prep | MacConnell | MiniPrep Machine | MP2400 | Available |
Description/Details: These bench-top instruments automatically purify plasmid DNA directly from bacterial culture in just over one hour. The instruments use pre-cast disposable sample cassettes, which fit into an internal electrophoresis processing rig. Each cassette can process up to twelve 2ml or 24 1ml bacterial culture samples. The Mini-Prep 24 processing rig holds two cassettes . Plasmid DNA obtained from these instruments is highly pure and can be used in most molecular biology processes, including manual and fluorescent automated DNA sequencing and transfection. With high-copy number plasmids, individual sample lanes of cassette typically yield 4-6µg of DNA from 2 mL of culture. ... |
|
|
 | 5490 | DNA:Sample Prep | Eppendorf | Perfectprep Vac Manifold | | Available |
Description/Details: Perfectprep Vac Manifold, Single () - Rapid and simple purification of BAC, PAC, fosmid and cosmid DNA. ... |
|
|
 | 5805 | DNA:Sample Prep | Qiagen | BioSprint 96 | 9000852 / 710 | Available |
Description/Details: For rapid and economical automated preparation of 1–96 samples using magnetic-particle technology
Purification of DNA from cells, tissues, blood, and plant material
Purification of viral DNA and RNA and bacterial DNA from veterinary samples
Cleanup of DNA from amplification reactions
Purification of 6xHis- or Strep-tagged proteins
Economically priced automation saves time and effort
The BioSprint 96 Workstation processes up to 96 samples per run. It comes preinstalled with protocols that enable sample preparation with BioSprint kits. The workstation controls an array of magnetic rods that can attract or release magnetic particles and transfer them from well to well. The sequential transfer of magnetic particles allows a rapid purification procedure to be performed, from the initial binding of target molecules (e.g., genomic DNA) to the particles, through to washing of the particles and elution of pure target molecules. Since the workstation transfers magnetic particles instead ... |
|
|
 | 4634 | DNA:Sample Prep:Card Filling Station | Applied Biosystems | Prism | 7700 | Available |
Description/Details: The Filling Station coordinates loading by first
exposing the channels of the reaction card to a vacuum and then
opening the evacuated card to a sample-specific PCR reaction mix.... |
|
|
 | 3762 | DNA:Sequencer | Applied Biosystems | Prism Analyzer | 3700 | Available |
Description/Details: The ABI Prism 3700 DNA Analyzer is an automated, high-throughput, capillary electrophoresis system that can separate, detect, and analyze up to 96 capillaries of fluorescently labeled DNA fragments in one run. ... |
|