 | 5399 | Heat Exchanger | Affinity | FLIPR Heat Exchanger | EWA-08BK-ED16CADO | Available |
Description/Details: Heat Exchange for FLIPR. Non-refrigerated Water to Water Heat Exchangers are designed to remove heat from a process and discharge it to an auxiliary facility water supply such as a central chilled water system or cooling tower. The E Series products deliver clean cool fluid with very tight temperature stability, constant flow and pressure to your water cooled equipment while rejecting the heat into the Facility stream. A 10 C temperature differential is required for most applications, and sizes are available up to 150KW. These products offer a very small footprint, and quiet clean operation, and with no refrigeration, they are very energy efficient. Available with a wide variety of pumps, controllers, and safety features, and can be constructed with a wide variety of materials to allow compatibility with many specialty fluids. ... |
|
|
 | 6037 | Microplate Handler | BMG | POLARstar Optima | w/Stacks | Available |
Description/Details: The POLARstar OPTIMA is a multidetection microplate reader with many features well-suited for life science laboratories. The POLARstar can read the following detection modes:
Fluorescence Polarization
Fluorescence Intensity – including FRET
Time-Resolved Fluorescence - DELFIA®
High-Performance Luminescence (flash and glow) – including BRET, DLReadyTM certified
Absorbance – UV/Vis with 1 cm path length correction
Simultaneous Dual Emission detection makes FP, FRET, and BRET assays faster and more precise. The POLARstar OPTIMA does not have to switch filters or polarizers to read the second channel thus making the read twice as fast as single channel microplate readers. And, since both channels are read at the same time the results are more precise. The POLARstar OPTIMA collects both emission vectors simultaneously for a fantastic speed advantage. ... |
|
|
 | 4449 | Microplate Reader:Absorbance | Tecan | Sunrise | | Available |
Description/Details: Sunrise is a versatile microplate absorbance reader for 96-well plates providing all the functionality needed for the numerous applications in diagnostics, biotechnology and research laboratories.
The Sunrise microplate reader has been designed to meet the 98/79/EC directive of the European Union for in-vitro diagnostic products and its compact space saving design makes it ideal for stand-alone use as well as integration into automated ELISA-systems such as the Freedom EVOlyzer®.
Options such as temperature control, different filter slides and a barcode scanner can be added to create a fully customized instrument configuration.
The Sunrise microplate reader can easily be controlled from an external PC in remote control mode using the advanced Magellan™ data reduction software.
... |
|
|
 | 5281 | Microplate Reader:Absorbance | Tecan | Spectra II | F039047 | Available |
Description/Details: Tecan Spectra II
Microplate reader. Computer controlled, measurement Time 6 seconds for single wavelength, 8 seconds for dual wavelength, 0 to 3.5 Abs, visual keyboard display with touch membrane panel for printer operation or add PC software for expanded detailed readings, 10-120/220-240V, 50/60Hz.
... |
|
|
 | 5283 | Microplate Reader:Absorbance | Tecan | Spectra II | B039.047 | Available |
Description/Details: Tecan Spectra II
Microplate reader. Computer controlled, measurement Time 6 seconds for single wavelength, 8 seconds for dual wavelength, 0 to 3.5 Abs, visual keyboard display with touch membrane panel for printer operation or add PC software for expanded detailed readings, 10-120/220-240V, 50/60Hz.
... |
|
|
 | 5282 | Microplate Reader:Absorbance | Tecan | Spectra II | F039047 | Available |
Description/Details: Tecan Spectra II
Microplate reader. Computer controlled, measurement Time 6 seconds for single wavelength, 8 seconds for dual wavelength, 0 to 3.5 Abs, visual keyboard display with touch membrane panel for printer operation or add PC software for expanded detailed readings, 10-120/220-240V, 50/60Hz.
... |
|
|
 | 5448 | Microplate Reader:Absorbance | Thermo Electron North America LLC | Multiskan Spectrum | | Available |
Description/Details: Designed for full coverage of spectrophotometric applications with the ability to read from visible to UV wavelengths, these photometers feature a built-in monochromator. This makes it easy to select any wavelength from 200nm to 1000nm in 1nm steps without ever changing a filter. Each unit reads the native absorbances of DNA, RNA, and proteins, and the narrow bandwith of just 2nm ensures consistently accurate absorbance measurements. Each unit also features complete robot compatibility for high-volume testing.
... |
|
|
 | 5641 | Microplate Reader:Absorbance | BioTek Instruments | PowerWave X | | Available |
Description/Details: Small footprint, huge features!
Instrument Description and Capabilities:
Monochromator optical design with powerful Xenon flash lamp
Select wavelengths from 200 to 999nm in 1 nm increments without the use of filters
96- and 384-well microplates
Typical Performance:
Accuracy: < 1% at 2.0 OD, < 2% at 3.0 OD
Linearity: +/- 1% from 0 to 3.0 OD
Repeatability: < 0.5% at 2.0 OD, < 2% at 3.0 OD
Specifications:
Microplates: Accomodates 96- and 384-well microplates
Read types: Endpoint, kinetic, spectral scanning and linear scanning
Read modes: Normal - multiple measurements are taken on each well, with enhanced performance at optical densities > 2.0 OD
Rapid - increased speed with the best performance from 0 to 2.0 OD
Sweep - "On the fly" measurement, for fastest possible screening
Absorbance measurement range: 0 - 4.0 OD
Wavelength measurement range: 200 - 999 nm.
Minimum read speed:
Normal - 96-well, 11 seconds; 384-well, 23 seconds
Sweep - 96-well, 5 seconds; 384-well,... |
|
|
 | 6349 | Microplate Reader:Absorbance | Molecular Devices MDS Analytical Technologies | Spectramax Plus | | Available |
Description/Details: |
|
|
 | 6448 | Microplate Reader:Absorbance | BioTek Instruments | Powerwave HT | | Available |
Description/Details: BioTek’s PowerWave HT microplate spectrophotometer is designed for use in a myriad of applications, from direct quantitation of nucleic acids using automated pathlength correction to full-scale high throughput operations that demand speed, accuracy and reliability. With rugged hardware, proven optical performance and a very small footprint, the PowerWave HT is uniquely designed to provide the most application flexibility while saving space both on the benchtop and in automated systems. Gen5 Data Analysis software comes with PowerWave HT, providing unsurpassed power and versatility.
Use PowerWave HT for applications requiring low UV measurements, such as direct DNA quantitation and purity testing, RNA quantitation, as well as basic ELISA’s, enzyme kinetics, colorimetric assays, spectral scanning and many other applications.
General
Detection method Absorbance
Read method End point, kinetic, spectral, linear scanning
Microplate types 96- & 384-well
Temperature control... |
|
|
 | 6449 | Microplate Reader:Absorbance | BioTek Instruments | Powerwave HT | | Available |
Description/Details: BioTek’s PowerWave HT microplate spectrophotometer is designed for use in a myriad of applications, from direct quantitation of nucleic acids using automated pathlength correction to full-scale high throughput operations that demand speed, accuracy and reliability. With rugged hardware, proven optical performance and a very small footprint, the PowerWave HT is uniquely designed to provide the most application flexibility while saving space both on the benchtop and in automated systems. Gen5 Data Analysis software comes with PowerWave HT, providing unsurpassed power and versatility.
Use PowerWave HT for applications requiring low UV measurements, such as direct DNA quantitation and purity testing, RNA quantitation, as well as basic ELISA’s, enzyme kinetics, colorimetric assays, spectral scanning and many other applications.
General
Detection method Absorbance
Read method End point, kinetic, spectral, linear scanning
Microplate types 96- & 384-well
Temperature control... |
|
|
 | 4933 | Microplate Reader:FLIPR Camera | Princeton Instruments | TE/CCD512TKEM | A0899309 | Available |
Description/Details: Camera for FLIPR System |
|
|
 | 5398 | Microplate Reader:Fluorescence | Molecular Devices MDS Analytical Technologies | FlexStation II | | Pending |
Description/Details: Specifications
Fluorescence Photometric
Emission Wavelength Range
360 - 850 nm
Excitation Wavelength Range
250 - 850 nm
Scanning Increments
1 nm
Sensitivity (Signal 3X STD DEV) Top Read (96-well plate) 3 fmol/well FITC
Sensitivity (Signal 3X STD DEV) Bottom Read (96-well plate) 8 fmol/well FITC*
Sensitivity (Signal 3X STD DEV) Top Read (384-well plate) 3 fmol/well FITC
Sensitivity (Signal 3X STD DEV) Bottom Read (384-well plate) 6 fmol/well FITC*
Time-Resolved Fluorescence (384-well plate) 0.5 fmol/well Eu-Ch*
Luminescence Photometric
Sensitivity 10 amol ALK Phos*
Wavelength Range 360 - 850 nm
General Photometric
Microplate Formats
6-, 12-, 24-, 48-, 96-, and 384-well
Detection Spot Size: Bottom Read
1.5 mm
Detection Spot Size: Top Read
3.5 mm
Lamp Life
Exp. 2 years, warr. 1 year
Mechanical
Read Time (Seconds)
< 9 (96 wells), < 29 (384 wells)
Single Column Read Frequency (96-Well)
1 Hz
Single Well Read Time Frequency
20 Hz
Shaker Time
0 to 999 seconds
Dimensions (... |
|
|
 | 5781 | Microplate Reader:Fluorescence | Molecular Devices MDS Analytical Technologies | Spectramax Gemini XS | | Available |
Description/Details: The SPECTRAmax™ GEMINI XS Dual-Scanning Microplate Spectrofluorometer can perform a variety of fluorescent applications as well as some time-resolved fluorescent and luminescent assays. The extreme flexibility and high sensitivity of the SPECTRAmax GEMINI XS make it appropriate for applications within the fields of biochemistry, cell biology, immunology, molecular biology, and microbiology. The SPECTRAmax GEMINI XS uses two holographic diffraction grating monochromators which allow for individual optimization of wavelengths for both excitation and emission. The dual-scanning capability can also be used to determine excitation and emission settings for new fluorescent probes. Mirrored optics focus the light into the sample volume and cutoff filters are used to reduce stray light and minimize background interference. The light source is a highpowered Xenon flashlamp; additional flexibility is provided by allowing a variable
number of lamp flashes per read.
Microplates having 6, 12... |
|
|
 | 6168 | Microplate Reader:Fluorescence | Molecular Devices MDS Analytical Technologies | FlexStation | Pipetting Head for FlexStation | Pending |
Description/Details: Specifications:
384-well Plates:
• Maximum Volume - 16 Channels: 30 µl
• Precision @ 10 µl - 16 Channels: 3% CV
• Precision @ 1 µl - 16 Channels: 5% CV
• Maximum Dispense Rate - 16 Channels: 52 µl/sec
... |
|
|
 | 6631 | Microplate Reader:Fluorescence | Molecular Devices MDS Analytical Technologies | FlexStation I | | Available |
Description/Details: Specifications
Fluorescence Photometric
Emission Wavelength Range
360 - 850 nm
Excitation Wavelength Range
250 - 850 nm
Scanning Increments
1 nm
Sensitivity (Signal 3X STD DEV) Top Read (96-well plate) 3 fmol/well FITC
Sensitivity (Signal 3X STD DEV) Bottom Read (96-well plate) 8 fmol/well FITC*
Sensitivity (Signal 3X STD DEV) Top Read (384-well plate) 3 fmol/well FITC
Sensitivity (Signal 3X STD DEV) Bottom Read (384-well plate) 6 fmol/well FITC*
Time-Resolved Fluorescence (384-well plate) 0.5 fmol/well Eu-Ch*
Luminescence Photometric
Sensitivity 10 amol ALK Phos*
Wavelength Range 360 - 850 nm
General Photometric
Microplate Formats
6-, 12-, 24-, 48-, 96-, and 384-well
Detection Spot Size: Bottom Read
1.5 mm
Detection Spot Size: Top Read
3.5 mm
Lamp Life
Exp. 2 years, warr. 1 year
Mechanical
Read Time (Seconds)
< 9 (96 wells), < 29 (384 wells)
Single Column Read Frequency (96-Well)
1 Hz
Single Well Read Time Frequency
20 Hz
Shaker Time
0 to 999 seconds
Dimensions (... |
|
|
 | 6177 | Microplate Reader:Fluorescence:Fluidics Module | Molecular Devices MDS Analytical Technologies | Fluidics Module | 0310-4043 304PT | Available |
Description/Details: |
|
|
 | 6197 | Microplate Reader:Liquid Scintillation | Perkin Elmer | Topcount NXT | C9912V0 | Available |
Description/Details: TopCount NXT with Windows 2000®-based operating software and built-in Hologram® relational database software, provides the maximum capability for both basic research and high throughput screening. The HTS version lets you count radioisotopic and luminescent samples twelve at a time in both 96- and 384-well microplates, separately or intermixed. In fact, you can continue to count and analyze assays in the 96-well format while you convert them to the 384-well microplate, and not lose productivity. The external plate stacker allows more than 15,000 samples to be loaded for the highest unattended counting capacity, or you can integrate your TopCount NXT into a robotic system for unlimited high throughput. Being Windows 2000-based, TopCount NXT is easily networked to provide error-free, automatic data transmission. Best of all, you’ll never lose data due to printer or network failures, because the built-in Hologram database automatically stores the data for every sample you ... |
|
|
 | 6207 | Microplate Reader:Liquid Scintillation | Perkin Elmer | Topcount NXT | C384V00 | Available |
Description/Details: TopCount NXT with Windows 2000®-based operating software and built-in Hologram® relational database software, provides the maximum capability for both basic research and high throughput screening. The HTS version lets you count radioisotopic and luminescent samples twelve at a time in both 96- and 384-well microplates, separately or intermixed. In fact, you can continue to count and analyze assays in the 96-well format while you convert them to the 384-well microplate, and not lose productivity. The external plate stacker allows more than 15,000 samples to be loaded for the highest unattended counting capacity, or you can integrate your TopCount NXT into a robotic system for unlimited high throughput. Being Windows 2000-based, TopCount NXT is easily networked to provide error-free, automatic data transmission. Best of all, you’ll never lose data due to printer or network failures, because the built-in Hologram database automatically stores the data for every sample you ... |
|
|
 | 5159 | Microplate Reader:Luminescence | Molecular Devices MDS Analytical Technologies | LMAX | 35333-27 | Available |
Description/Details: The Lmax Microplate Luminometer is designed for the bio- and chemiluminescence measurements using 96-well and 384-well microplates. This instrument is also suitable for glow luminescence measurements in both 96- and 384-well plates. It is also suitable for measuring flash luminescence in 96-well plates. The system is equipped with 2 injectors with variable volumes. (The injection system can only be used with 96-well plates).... |
|