 | 5647 | Chromatography:Cross-Flow Filtration | Amersham Biosciences | AKTA Crossflow | | Available |
Description/Details: ÄKTAcrossflow is the first fully automated system for cross flow filtration process development and is ideal for filter screening and process optimization at small-scale. ÄKTAcrossflow together with UNICORN control software puts you in control of your cross fl ow process to allow consistent simulation of large-scale conditions and provide data for comprehensive analysis of results. The benefits of working with ÄKTAcrossflow include:
• Broad range of applications that cover ultra filtration and microfiltration
• Flexible operation of either hollow fiber cartridges or cross flow cassettes
• Thorough and efficient process development with full TMP and flux scouting
• Single familiar UNICORN interface for both chromatography and membrane separations
• No disruption to proteins or cells with low shear force pumps that require no cooling
• Minimum working volume of 25 ml ensures operation of complete processes using filters between 40 cm2 a... |
|
|
 | 5998 | Chromatography:Dual Pulse Stimulator | Harvard Apparatus | 50-6012 | | Available |
Description/Details: This unit has a wider frequency range of 0.1 to 1000Hz and a dual pulse function. When dual pulse mode is selected a secondary pulse is generated behind the initial pulse; a delay circuit controls the time difference between the two pulses. The 6012 is also capable of producing Tetanic Train Pulses internally without the need to utilise any other external triggering.
Specifications
Frequency Range 0.1 to 1000 Hz in 4 ranges
Pulse Width Range 0.1 to 5mS in 6 preset steps
Dual Pulse Delay 0 to 1000 mS
Output Amplitude 0 to 0.5 Volts, 0 to 5 Volts or 0 to 50 Volts
Rise and Fall Time > 5 μ sec
Gate In Short Circuit or 12 Volt (Max) Logic Pulse
(triggers on falling edge)
Connections 2 x insulated 4 mm sockets (Output)
3 x BNC Socket (Gate & Sync Connections)
Power 110-115 Volts 60Hz or 220-230 Volts 50Hz... |
|
|
 | 3800 | Chromatography:FPLC:FPLC System | Perseptive Biosystems | Biocad 700E | 5-1004-75 | Available |
Description/Details: BioCad is a classic. First came the 'FPLC', then came the Econo System...but there is still only one BioCAD -intelligent biomolecule purifications system. A classic paradigm shift in purification. The powerful BioCAD workstation--the system which set an industry standard using automated templates for optimizing purification protocols.
It enables accelerated methods development through systematic exploration of key parameters affecting a separation. ... |
|
|
 | 5094 | Chromatography:FPLC:Pump | Pharmacia Biotech | Pump P-50 | 19-1992-01 | Available |
Description/Details: Description : Pharmacia P-50 (P50) HiLoad Pump Flow rate 0.1-49.9 ml/min Operating pressure 0.5 Mpa Works well with viscous biological materials. ... |
|
|
 | 2851 | Chromatography:HPLC | Agilent Technologies | G1314A | LC Detector | Available |
Description/Details: Whether as a stand alone detector extending your analytical range, or in an automated Agilent 1100 Series system enhancing your productivity, the 1100 Series variable wavelength detector (VWD) lowers detection limits with simplified optics for high sensitivity, low baseline drift and wide linear range. Lower your cost of ownership with easy front access to lamp and flow cell for fast replacement. Helps to comply to GLP with built-in holmium oxide filter for automatic wavelength verification. ... |
|
|
 | 3330 | Chromatography:HPLC | Hewlett Packard | 1050 | 79855A Autosampler | Available |
Description/Details: Hewlett Packard 1050 Autosampler features include digital display, multi-functional keypad and more. The rear of the unit has 2 remote, RS-232, HP-IB and a BCD output port. ... |
|
|
 | 4184 | Chromatography:HPLC | Hewlett Packard | 1050 | 79853C Absorbance Detector | Available |
Description/Details: The 1050 Variable Wavelength Detector (VWD) is a detector of the modular
type liquid chromatograph 1050 Series. This is a standalone
grating/photodiode type general purpose detector. The performance and
features match the requirements of the routine analysis and QC/QA analysis.
The 1050 VWD is a standard size detector of 1050 modular type LC series and
can be build up with other LC modules, such as pump and automatic sampler.
Since it is standalone type, it can be also used as an ordinary LC detector. It
has a functional keyboard and 16-character fluorescent display which
provides you easy operation.... |
|
|
 | 2825 | Chromatography:HPLC | Agilent Technologies | G1306A | Absorbance Detector | Available |
Description/Details: The 1050 Diode Array Detector (G1306A DAD) and Multiple Wavelength Detector (79854A MWD) module houses the optical system and the electronic circuitry which acquire and process absorbance data. Control of optics (radiation source shutter photo diode array etc.) is an integral part of the electronics. The module is controlled through the user interface through which the operator defines his requirements (detection parameters etc.) and through which the system presents the required analytical information.... |
|
|
 | 2215 | Chromatography:HPLC | Rainin | Dynamax | Absorbance Detector UV-1 | Available |
Description/Details: In developing the DYNAMAX MODEL UV-1 the inventors of the absorbance detector isolated five primary characteristics of flashlamps which contribute to absorbance noise in high sensitivity absorbance detectors. They are:
(1) light amplitude variations flash to flash,
(2) flashlamp arc position variations from flash to flash,
(3) spatial intensity variations across the surface of the flashlamp arc from flash to flash,
(4) angular light pattern variations from flash to flash, and
(5) light spectrum variations from flash to flash.
In the DYNAMAX MODEL UV-1, each of the foregoing noise characteristics is minimized to produce an absorbance detector having a noise specification of less than 2×10-5 AU. The first of the above-listed noise characteristics may be compensated for by improved electronics while optics with low spatial sensitivity and improved flow cell design may minimize the effects of the second and third noise characteristics. In accordance with the present invention, n... |
|
|
 | 2216 | Chromatography:HPLC | Rainin | Dynamax | Pump SD-200 | Available |
Description/Details: Dynamax Solvent Delivery System, Model No. SD-200. This Dynamax Solvent Delivery System features include: Digital Display, main menu soft key controls, solvent pump.... |
|
|
 | 2219 | Chromatography:HPLC | Rainin | Dynamax | Pump SD-200 | Available |
Description/Details: Dynamax Solvent Delivery System, Model No. SD-200. This Dynamax Solvent Delivery System features include: Digital Display, main menu soft key controls, solvent pump.... |
|
|
 | 4596 | Chromatography:HPLC | Perkin Elmer | ISS-200 | Autosampler | Available |
Description/Details: The Perkin Elmer ISS 200 Auto sampler HPLC Auto injector is Non-pneumatic and fully-programmable. It can be controlled by PE-Nelson Turbo Chrom software. ... |
|
|
 | 4873 | Chromatography:HPLC | Agilent Technologies | G1311A | LC Pump | Available |
Description/Details: Quaternary Pump with a flow range of 0.1 to 10.0 ml/min and a maximum operating pressure of 5800psi (400 Bar).
This pump has 4 solvent inlets and built in gradient control.
It also can be remotely controlled by external equipment.
The gradient formation is performed by a low pressure gradient valve.
Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve
Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments
Flow range: 0.2 – 10.0 ml/min
Recommended pH range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800 – 1100 μl, dependent on back pressure
... |
|
|
 | 4740 | Chromatography:HPLC | Rainin | Dynamax | Absorbance Detector UV-1 | Available |
Description/Details: Rainin Dynamax UV-1 Absorbance Detector Chromatography:Liquid
In developing the DYNAMAX MODEL UV-1 the inventors of the absorbance detector isolated five primary characteristics of flashlamps which contribute to absorbance noise in high sensitivity absorbance detectors. They are:
(1) light amplitude variations flash to flash,
(2) flashlamp arc position variations from flash to flash,
(3) spatial intensity variations across the surface of the flashlamp arc from flash to flash,
(4) angular light pattern variations from flash to flash, and
(5) light spectrum variations from flash to flash.
In the DYNAMAX MODEL UV-1, each of the foregoing noise characteristics is minimized to produce an absorbance detector having a noise specification of less than 2×10-5 AU. The first of the above-listed noise characteristics may be compensated for by improved electronics while optics with low spatial sensitivity and improved flow cell design may minimize the effects of the second and third nois... |
|
|
 | 4784 | Chromatography:HPLC | Rainin | Dynamax | Pump SD-200 | Available |
Description/Details: Dynamax Solvent Delivery System, Model No. SD-200. This Dynamax Solvent Delivery System features include: Digital Display, main menu soft key controls, solvent pump.... |
|
|
 | 4785 | Chromatography:HPLC | Rainin | Dynamax | Pump SD-200 | Available |
Description/Details: Dynamax Solvent Delivery System, Model No. SD-200. This Dynamax Solvent Delivery System features include: Digital Display, main menu soft key controls, solvent pump.... |
|
|
 | 4786 | Chromatography:HPLC | Rainin | Dynamax | Pump SD-200 | Available |
Description/Details: Dynamax Solvent Delivery System, Model No. SD-200. This Dynamax Solvent Delivery System features include: Digital Display, main menu soft key controls, solvent pump.... |
|
|
 | 4787 | Chromatography:HPLC | Rainin | Dynamax | Pump SD-200 | Available |
Description/Details: Dynamax Solvent Delivery System, Model No. SD-200. This Dynamax Solvent Delivery System features include: Digital Display, main menu soft key controls, solvent pump.... |
|
|
 | 4808 | Chromatography:HPLC | Rainin | Dynamax | Absorbance Detector UV-1 | Available |
Description/Details: In the DYNAMAX MODEL UV-1, each of the foregoing noise characteristics is minimized to produce an absorbance detector having a noise specification of less than 2×10-5 AU.
The first of the noise characteristics may be compensated for by improved electronics while optics with low spatial sensitivity and improved flow cell design may minimize the effects of the second and third noise characteristics.
In accordance with the present invention, noise associated with the third, fourth and fifth noise characteristics are substantially eliminated by the inclusion of a unique reflecting beam splitter with highly polished mirror surfaces and splitter and flow cell masks in the optics system of the DYNAMAX MODEL UV-1.
Operating voltage:230V... |
|
|
 | 4872 | Chromatography:HPLC | Agilent Technologies | G1313A | LC Autosampler | Available |
Description/Details: Application area
Designed for the reliability, safety, and ease of use needed in pharmaceutical routine tasks and quality control, as well as for environmental and food analyses.
Features
* Reliable injections from 0.1 µL to 100 µL
* Easy adaption for injection volumes up to 1500 µL for applications ranging from microbore to semipreparative chromatography
* Low internal volume of 300 µL for the minimum contribution to a system's total internal volume
* Overlapped injections for increased productivity
Sample capacity
* 100 × 2-mL vials in a standard tray
* 40 × 2-mL vials in a standard tray
* 15 × 6-mL vials in a half tray
* Microvials (100 or 300 µL) with sleeves
Carryover
* Typically < 0.1 % without automated needle wash, typically < 0.05 % with automated needle wash. ... |
|